- High speed and high accuracy power measurements
- Compliance quality harmonics analysis to EN61000-3-2
- Compliance quality flicker measurement to EN61000-3-3

Overview
The AC2000 is a fast, easy to use mains and harmonics analyser with
full graphical display. It is capable of continuous real-time analysis
of both voltage and current.
As a general purpose mains analyser it can measure Watts, VA Vrms,
Vpk, Arms, Apk, Crest factors, THD, Power factor, Frequency and Inrush
current.
As a harmonics analyser it is a quick and convenient instrument for
pre-compliance measurements using normal mains supply and is capable
of full compliance measurements to EN61000-3-2
in conjunction with a suitable power source.
Capabilities include real-time Class D evaluation and visual display,
continuous automatic calculation of harmonic limits to EN61000-3-2,
inrush current analysis, and timed test sequences with analysis of fluctuating
harmonics.
As an option, the AC2000 can be operated as a conformance quality
flicker meter in conformance with EN60868 and EN61000-3-3.
A printer interface is included for record keeping and archiving, along
with an RS-232 interface and an optional IEEE-488 interface for use
with PC based software or as part of a GPIB system.
High performance power analyser
The AC2000 is a high speed, high accuracy ac power analyser for single
phase supplies of up to 16 amps RMS.
The supply to be measured is connected via a dedicated input cable
independently of the supply to the instrument.
The output to the load is via a front panel mounted standard’ mains
connector. A wide range of power connectors is available including most
European national types.
The AC2000 can measure Watts, VA, Volts rms, Volts peak, Amps rms,
Amps peak, Crest factors, THD, Power factor, Frequency and Inrush current.
The large display can show multiple parameters simultaneously along
with graphical representations of voltage and current waveforms.
Compliance-quality harmonics analyser
From 1st January 2001 all electrical equipment sold within the EEC
will have to comply with legislation relating to the harmonics content
of the current waveform.
The AC2000 has been designed to make these measurements both quick
and simple. It measures harmonics from the 1st to the 40th and updates
the display in real time.
It is suitable for pre-compliance measurements using a normal mains
supply and is capable of full compliance measurements to EN61000-3-2
in conjunction with a suitable power source (such as the AC1000
).
Capabilities include real-time Class D evaluation and visual display,
continuous automatic calculation of harmonic limits to EN61000-3-2,
inrush current analysis, and timed test sequences with analysis of fluctuating
harmonics.

Compliance-quality flicker meter
The AC2000 has the optional capability to operate as a compliance quality
flicker meter in conformance with EN60868 and EN61000-3-3.
A current measurement method can be used rather than voltage measurement
thus eliminating the need for a reference impedance.
Flicker severity can be
measured in terms of P
st
and P
lt
with analysis periods variable between 5 minutes and 2 hours.
The graphical display can show Cumulative Probability, Voltage Deviation
Failure as well as P
st
values.
A full range of interfaces
A printer interface is included for record keeping and archiving, along
with RS-232 (standard) and IEEE-488 (optional) interfaces for use with
PC based software or as part of a GPIB system.
Software is also available that enables results to be displayed, recorded
and documented using a PC.
| Mains Analyser |
| Measurement Circuit: |
Single Phase with standard mains connector. |
| Current Rating: |
16A rms continuous, or national connector rating if lower. |
| Voltage Ranges: |
115V (±200V pk) 230V (±400V pk). |
| Current Ranges: |
±24mA pk to ±400A pk in fifteen 2:1 ranges |
| Frequency Range: |
45 - 66 Hz. |
| Shunt Resistance: |
3m ohms. |
| Sampling Rate: |
300 points per cycle. |
| Basic Accuracy: |
<0.2%. |
| Measured Parameters: |
Vrms, Vpk, Arms, Apk, Crest factors, THD, W, VA, Power factor,
Frequency, Inrush current. |
| Monitor Outputs: |
Re-constructed Voltage and current signals |
| Harmonics Analyser |
| Measurements: |
1
st
harmonic to 40
th
harmonic. |
| Current Rating: |
16A rms continuous, or national connector rating if lower. |
| Voltage Ranges: |
115V (±200V pk) 230V (±400V pk). |
| Current Ranges: |
±24mA pk to ±400A pk in fifteen 2:1 ranges |
| Frequency Range: |
45 - 66 Hz. |
| Shunt Resistance: |
3m ohms. |
| Sampling Rate: |
300 points per cycle. |
| Basic Accuracy: |
Better than 5% of limit or 0.2% of selected range whichever is
the greater. |
| Display Modes: |
Numeric readout of parameters.
Graphical Waveform display with accumulate and max.
Hold facilities and class D mask.
Tabular and Histogram harmonic analysis with comparison to limits
in the standards.
|
| Flicker Meter (Option) |
|
Measurement:
|
P
st
and P
lt
to EN60686 and EN61000-3-3. |
| Current Rating: |
16A rms continuous, or national connector rating if lower. |
| Voltage Ranges: |
115V (±200V pk) 230V (±400V pk). |
| Current Ranges: |
±24mA pk to ±400A pk in fifteen 2:1 ranges |
| Frequency Range: |
45 - 66 Hz. |
| Shunt Resistance: |
3m ohms. |
| Sampling Rate: |
300 points per cycle. |
| General |
| Display: |
320 x 240 pixel backlit LCD. |
| Interfaces: |
Parallel Printer, RS232, Optional IEEE-488 (GPIB). |
| Instrument Supply: |
230V or 115V ±14%, 48 to 65 Hz. |
| Operating Range: |
+5°C to 40°C, 20-80% RH. |
| Storage Range |
-10°C to +60°C |
| Dimensions: |
305 x 148 x 220mm (WxHxD) |
| Weight: |
4.2kg |
| Safety: |
Complies with EN61010-1 |
| EMC Compliance: |
Complies with EN61326-1 |